What each leg of a sling is really carrying SLING
A two-leg sling at sixty degrees from vertical puts the whole weight of the load into each leg. Not half of it. That is why sixty degrees is the limit.
The lift
What it comes to
The same lift at five angles
The working
EN 13414 and EN 1492 mode factors and the sixty degree limit. The sling, its condition, its certificate and the lift plan are a competent person’s.
How it works
Each leg never carries the load divided by the number of legs
Two things make it more than that, and both are routinely ignored at the hook.
The angle. A leg at an angle carries the load divided by the cosine of that angle. At 30° from vertical a two-leg sling puts about 58% of the load into each leg; at 45°, 71%; at 60°, a full 100%: each leg is carrying the entire weight of the load, not half of it. Sixty degrees is the limit in the standard, and that is exactly why: at that point a two-leg sling has stopped sharing anything at all.
The count. A four-leg sling is rated as though three legs are working. On a rigid load with fixed-length legs, three of them find the load first and the fourth is along for the ride, which three depends on how the load sits and can change during the lift. The mode factors in EN 13414 and EN 1492 build that in, which is why a four-leg sling is not rated at twice a two-leg one.
The squeeze nobody calculates
The same angle that increases the tension also pulls the top of the load inwards, and that horizontal component is often what actually breaks something. At 60° the inward force is about 1.7 times the load, applied to the lifting points and to whatever is between them.
On a crate, a frame, a cabinet or anything with a hollow section, that is frequently the failure: the load is not overloaded vertically, it is crushed sideways. A spreader beam removes it entirely by taking the horizontal force into the beam instead of into the load, which is what a spreader is for, not to make the sling reach.
Working within it
Measure the angle rather than estimating it. People consistently underestimate angles at the hook, in the direction that matters, and the error is largest exactly where the cosine is changing fastest.
Shorter legs mean bigger angles. The instinct to shorten a sling so it is tidier is the instinct that pushes the angle past the limit, and the honest answer to a sling that is too long is a longer hook height or a spreader, not a tighter angle.
Check the lifting points as well as the sling. The rating you looked up is for the sling; the eyebolt, the shackle and the point it is welded to have ratings of their own, and an eyebolt loaded at an angle is derated sharply, often to a quarter of its straight pull.
And treat this as the arithmetic, not the plan. The lift plan, the condition of the gear, the examination record, and whether the weight you were given is the real weight are all outside anything a calculator can see. The weight in particular: a figure from a drawing is a figure for the thing as drawn, without the contents, the water in it, or the frame it is bolted to.
Nothing is uploaded. Nearby: TORQUE on what a bolt is really being tightened to, AXLE and BALANCE for the vehicle it goes on, and PALLET for how it is stacked.
The guide: Why a four-leg sling is rated on three legs
Questions people ask about SLING
Why does the angle matter so much?
Because a leg at an angle carries the load divided by the cosine of that angle. At thirty degrees from the vertical that is fifteen per cent more than the share; at forty-five it is forty-one per cent more; at sixty it is double. So a two-leg sling at sixty degrees is putting the entire weight of the load into each leg, and there is nothing left of the sharing the second leg was supposed to provide.
Why is a four-leg sling rated as three?
Because on a rigid load with fixed-length legs, three of them take up the load first and the fourth is a passenger until one of the three lets go. The standard builds that into the mode factor rather than pretending otherwise, which is why a four-leg assembly is not twice a two-leg one.
What is the squeeze figure?
The horizontal force each leg is putting into the top of the load, pulling inwards. It is the vertical share times the tangent of the angle, so at forty-five degrees it equals the lift and at sixty it exceeds it. It is what folds a crate, buckles a frame or caves in a machine’s casing on the way up, and it is almost never calculated because nothing calculates it.
What does an off-centre load do?
It loads the legs unevenly, by moments. A centre of gravity twice as far from one attachment point as the other puts two thirds of the weight on the near leg, and that leg is the one that has to be within its rating. The page shows the share and uses the worse one.
Is this a lift plan?
No. It is the arithmetic a lift plan rests on, done correctly and shown in full, on a device that sends nothing anywhere. The sling itself, its condition, its certificate and the plan are a competent person’s.
Doing this often? The OBSCURA Engineering Suite models the load as a part and reports its mass, centre of mass and inertia in any of ten materials. On its own, US$2 a month; with everything else, US$5 a month or US$48 a year.