List what separates the room from somewhere colder. A wall to a heated room loses nothing and can be left out; one to an unheated garage takes the garage’s temperature. The U-values come from the building’s drawings or an energy assessment: a solid brick wall is around 2, a new insulated one under 0.3, double glazing 1.2 to 2.8.

What size

The working


    

Heating is the steady-state heat loss of BS EN 12831 and CIBSE Guide A in its plainest form: U × A × ΔT for each element, and 0.33 × air changes × volume × ΔT for the air, with no thermal bridges and no margin for heating that goes off at night. Cooling is the ENERGY STAR sizing chart for a room unit, not a Manual J calculation. One watt is 3.412142 BTU an hour.

How it works

BTU works out how big a heater or a room air conditioner a room needs. Heating comes from the room's heat loss: U-value times area times temperature difference for each wall, window and floor, plus the air. Cooling comes from the ENERGY STAR sizing chart with its own adjustments. It gives watts and BTU an hour, and the measurements stay in this tab.