How long a room takes to empty, and with which door gone EVACUATE
A hall with three wide doors is fine on paper and a different building with the best one gone. That second sum is the whole reason for doing the first.
The building
The rooms
Widths are the clear width between the door stops, not the frame. Travel is the distance from the furthest point in the room to a door, which is added to the queueing time rather than hidden inside it.
With and without the best door
The working
Widths follow the published step table: 750 mm serves 60 people, 850 serves 110, 1050 serves 220, and more people than that need 5 mm each. This is arithmetic, shown and checkable, rather than a fire risk assessment.
How it works
EVACUATE works out how long a room or building takes to empty, and checks it again with the largest exit out of use, because a fire can block the best door. Enter the occupants and the exits, and it gives the evacuation time with every exit and with the biggest one discounted. It is a planning aid, not a replacement for a fire risk assessment. The figures stay in this tab.
The guide: How much clearance you need below a fall arrest anchor
Questions people ask about EVACUATE
Why discount the largest exit?
Because the fire is allowed to be at it. An assessment that assumes every door is available assumes the one thing an emergency will not give you, and the room with three wide doors that comfortably passes is a different room with the best one blocked. Doing the second sum is the point of doing the first.
What is the difference between capacity and clearance time?
Capacity is a limit from a table: how many people a door of that width may serve at all. Clearance time is a rate: how long the queue takes. They answer different questions and they fail independently. A room can satisfy the table and still take four minutes to empty, and a room can empty in ninety seconds and be over-occupied for its doors, so both are shown.
Where does eighty people a minute come from?
It is the flow rate per metre of clear width that the research settles on and the guidance is built from. It is exposed as a setting because a crowd of schoolchildren, a crowd leaving a bar at closing time and a crowd containing wheelchairs are not the same crowd, and pretending one figure covers all three is how an assessment becomes decorative.
Why is travel time separate?
Because it is a real number of seconds that happens before anybody joins a queue, and in a long room it is substantial. Adding it to the flow time rather than folding it in means you can see which of the two is the problem: a distance issue is fixed by another door somewhere else, a flow issue by a wider one.
Is this a fire risk assessment?
No. It is the arithmetic an assessment rests on, done correctly, shown in full, and never sent anywhere. Occupancy figures, the condition of the doors, the alarm, the wayfinding and the people are the assessor’s judgement.